Nanoplasmonics · Week 6 · Lecture 6

Exciting Surface Plasmon Polaritons: Phase Matching and SPR Sensing

Light from air cannot launch a surface plasmon on a flat metal. A prism or a grating supplies the missing momentum — and the resulting dip becomes a molecular scale.
Undergraduate course · 16 weeks
sample (water), n = 1.333 glass prism 50 nm gold p-polarized light reflected: dark at θSPR
Recap of lecture 5

Last time: the surface plasmon polariton on one interface

\[ \beta = k_0\sqrt{\frac{\varepsilon_d\,\varepsilon_m}{\varepsilon_d+\varepsilon_m}}, \qquad k_0 = \frac{\omega}{c} = \frac{2\pi}{\lambda_0} \]
  • TM polarization only; bound only if εm′ < −εd
  • β > k0√εd: the SPP lies to the right of the light line
  • Propagation length L = 1/(2β″)

Gold / air at 633 nm (εm ≈ −11.8 + 1.2i)

neff = β′/k0 ≈ 1.045 · L ≈ 10 µm · field reaches ≈ 330 nm into air and ≈ 28 nm into gold

Today's question

Shine a laser from air onto a flat gold surface — at any angle, with p-polarization. The SPP is never excited. Why?

And how do we fix it, so that we can use SPPs in the lab?

Short answer

The SPP has more momentum along the surface than any light wave in air can supply. We must add momentum: with a prism (evanescent wave) or a grating (periodic kick).

Roadmap

Today's logic: from a mismatch to a molecular scale

Mismatchk0 sin θ < β
→
Prism couplingevanescent wave, Kretschmann / Otto
→
Reflectance dipthree-layer Fresnel, θSPR
→
Grating & othersk0 sin θ + mG = ±Re β
→
SPR sensingΔθ = S Δn
→
Instrumentssensorgrams, imaging

By the end of this lecture you can…

  • explain with a dispersion diagram why free light cannot excite an SPP on a flat surface;
  • derive the evanescent wave of total internal reflection and the prism resonance condition k0np sin θ = Re β;
  • compute the Kretschmann reflectance dip with the three-layer Fresnel formula, and explain the role of film thickness;
  • design a grating coupler (find the period Λ);
  • derive the angular sensitivity of an SPR sensor and evaluate it for gold in water.
Derivation · the momentum mismatch

Why light from air cannot launch an SPP on a flat surface

1
Light in air at angle θ: only the in-plane part matters,\[ k_x = k_0\sin\theta \;\le\; k_0 \]
A flat surface is the same everywhere along x, so kx is conserved.
2
The SPP needs kx = β. With εm < −εd, the fraction εm/(εd+εm) > 1, so\[ \beta = k_0\sqrt{\varepsilon_d}\sqrt{\tfrac{\varepsilon_m}{\varepsilon_d+\varepsilon_m}} \;>\; k_0\sqrt{\varepsilon_d} \]
3
Compare (air, εd = 1): \(k_0\sin\theta \le k_0 < \beta\). No angle works.
Gold, 633 nm: β = 1.045 k0 — only 4.5% short, but still impossible.
4
Fix: raise kx. In glass, \(k_x = k_0 n_p\sin\theta\) can reach 1.515 k0; or add a grating vector 2π/Λ.
kx c/ωp → ω/ωp

Swing analogy. To push a child on a swing you must match the rhythm (frequency ω). To push a whole row of swings in a wave, you must also match the spacing along the row (kx). Light from air has the right ω but too long an in-plane wavelength.

Derivation · total internal reflection

The evanescent wave carries kx larger than k0

1
In the prism (index np), light at angle θ has\[ k_x = k_0\,n_p\sin\theta \]
kx is the same on both sides of a flat interface (that is Snell's law).
2
Above (index n2): \(k_x^2 + k_{z2}^2 = n_2^2k_0^2\), so\[ k_{z2}^2 = k_0^2\left(n_2^2 - n_p^2\sin^2\theta\right) \]
3
Beyond the critical angle, np sin θ > n2: kz2² < 0, so kz2 = iκ:\[ E \propto e^{ik_xx}\,e^{-\kappa z}, \quad \kappa = k_0\sqrt{n_p^2\sin^2\theta - n_2^2} \]
A wave along the surface, decaying away from it: evanescent.
4
Numbers (BK7, np = 1.515, into air, θ = 45°): kx = 1.071 k0 > k0; decay length 1/κ ≈ 262 nm at 633 nm.
air, n₂ = 1 glass, np = 1.515 100% reflected 1/κ
Frustrated total internal reflection between two prisms
J. Magnus / G. Shapiro · public domain

Physical meaning

No energy flows up, but the field is there — with kx > k0. Bring a second surface close and light tunnels across (frustrated TIR). Bring a metal film close and an SPP can take the energy.

Prism coupling · two geometries (1968)

Kretschmann and Otto: two ways to bring the evanescent wave to the metal

sample: water, buffer, gas (ns) gold film, d ≈ 50 nm prism np SPP on the outer side →

Kretschmann–Raether

The metal film sits on the prism. The evanescent field tunnels through the thin film and excites the SPP at the metal–sample interface. Easy to build; the standard for sensors.

thick metal (or single crystal) air gap ≈ 0.3–1 µm prism np

Otto

A thin gap separates prism and metal. The evanescent field crosses the gap and excites the SPP on the metal surface facing the prism. The metal is untouched — good for crystal surfaces — but the gap is hard to control.

Physical meaning

In both cases the SPP is excited by tunneling: the coupling layer (film or gap) must be thin enough to let the evanescent field through, but thick enough not to spoil the SPP. This trade-off sets d ≈ 50 nm for gold at 633 nm.

Derivation · the resonance angle

Phase matching in a prism: k0 np sin θSPR = Re β

1
Match the in-plane wave vector of the evanescent wave to the SPP on the metal–sample side:\[ k_0\,n_p\sin\theta_{\text{SPR}} = \operatorname{Re}\beta = k_0\,\operatorname{Re}\sqrt{\frac{\varepsilon_m\varepsilon_s}{\varepsilon_m+\varepsilon_s}} \]
k0 cancels: only indices are left.
2
Insert water (εs = 1.333² = 1.777) and gold at 633 nm (εm = −11.8 + 1.2i):\[ \frac{\varepsilon_m\varepsilon_s}{\varepsilon_m+\varepsilon_s} = \frac{-20.97 + 2.13i}{-10.02 + 1.20i} = 2.087 + 0.037i \]
3
Square root: \(\beta/k_0 = 1.445 + 0.013i \;\Rightarrow\; n_{\text{eff}} = \beta'/k_0 = 1.445\)
Imaginary part → L = 1/(2β″) ≈ 3.9 µm in water.
4
Solve for the angle (BK7, np = 1.515):\[ \sin\theta_{\text{SPR}} = \frac{1.445}{1.515} = 0.954 \;\Rightarrow\; \theta_{\text{SPR}} \approx 72.5^\circ \]

Sanity check ✓

Need np > neff: 1.515 > 1.445 ✓ — otherwise no angle works.
Above TIR: θc = arcsin(1.333/1.515) = 61.6° < 72.5° < 90° ✓
Air instead of water: neff = 1.045 → θSPR = 43.6°.

Physical meaning

The resonance angle is a direct readout of neff, and neff depends on the sample index. Changing air to water moves the angle by about 29°. A thin molecular layer moves it by a tiny but measurable amount: this is the basis of SPR sensing.

This is the angle for a bare interface. The prism and the finite film shift it slightly — the full calculation is on the next slide.

Calculation · three-layer Fresnel (Airy) formula

The Kretschmann reflectance: a sharp dip at θSPR

\[ r = \frac{r_{12} + r_{23}\,e^{2ik_{z2}d}}{1 + r_{12}\,r_{23}\,e^{2ik_{z2}d}}, \qquad R = |r|^2 \]
1
Layers: 1 = prism, 2 = gold (thickness d), 3 = water. Same kx = k0np sin θ in all three.
2
Normal wave vectors and TM (p) interface coefficients:\[ k_{zj} = \sqrt{\varepsilon_jk_0^2 - k_x^2}, \quad r_{ij} = \frac{k_{zi}/\varepsilon_i - k_{zj}/\varepsilon_j}{k_{zi}/\varepsilon_i + k_{zj}/\varepsilon_j} \]
3
Sum of all bounces inside the film (a geometric series) gives the formula above.
Same idea as a Fabry–Pérot; here the film is lossy and kz3 is imaginary.
— d = 50 nm- - d = 30 nm··· d = 70 nm angle in prism θ (degrees) R (p-pol.)

Film thickness (computed): 30 nm → broad, Rmin = 0.39 · 50 nm → Rmin = 0.006 at 72.2° · 70 nm → shallow, Rmin = 0.44. BK7 | Au (−11.8 + 1.2i) | water, 633 nm.

Physical meaning · where does the light go?

At the dip, light is handed to the SPP and becomes heat

in: 100% reflected: 0.6% SPP, decays within L ≈ 2.5 µm → on the 50 nm film (absorption alone: 3.9 µm;leakage back into the prism shortens it —at critical coupling the two losses are equal) heat in gold water: evanescent only,no transmitted beam

Energy budget at θ = 72.2°

T = 0 (TIR into water) · R = 0.6% · absorbed A = 1 − R = 99.4%. Nearly all the light ends up as heat in a 50 nm film — carried there by the SPP.

Two ways the SPP loses energy

Absorption in the metal (rate set by ε″).
Leakage back through the film into the prism (rate grows as the film gets thinner). The leaked light is exactly out of phase with the directly reflected light.

Critical coupling

When leakage = absorption, the leaked and reflected waves cancel: R → 0. Thin film (30 nm): leakage too strong → broad, shallow. Thick film (70 nm): leakage too weak → narrow but shallow. Gold at 633 nm: d ≈ 50 nm.

Physical meaning

The dark reflection is not "missing" light: the SPP carries the energy along the surface and the metal absorbs it. Leakage also pulls the dip: 72.2° (film) vs 72.5° (bare interface).

Derivation · grating coupling

A grating adds momentum in steps of 2π/Λ

1
Periodic surface (period Λ) → the field picks up harmonics \(e^{imGx}\), with \(G = 2\pi/\Lambda\):\[ k_{x,m} = k_0\sin\theta + m\,G, \qquad m = 0, \pm1, \pm2, \dots \]
Like X-ray diffraction: a lattice adds reciprocal lattice vectors.
2
Phase matching with one order:\[ k_0\sin\theta + m\,\frac{2\pi}{\Lambda} = \pm\operatorname{Re}\beta \]
± : the SPP may run in +x or −x.
3
Normal incidence (θ = 0, m = ±1):\[ \Lambda = \frac{2\pi}{\operatorname{Re}\beta} = \frac{\lambda_0}{n_{\text{eff}}} = \lambda_{\text{SPP}} \]
4
Gold / air, 633 nm, neff = 1.0447: Λ = 633/1.0447 ≈ 606 nm.
Tilt to θ = 10° (m = ±1): Λ = λ0/(neff ∓ sin θ) = 727 nm (m = +1, SPP along +x) or 520 nm (m = −1, SPP along −x).
light, θ = 0 m = +1: SPP →← SPP: m = −1

Sanity check ✓

Λ ≈ λ0 makes sense: the grating must "print" the SPP wavelength, 606 nm, which is 4.5% shorter than 633 nm. In water, neff = 1.445 → Λ = 438 nm.

Physical meaning

The grating gives a periodic kick of 2π/Λ. It works in both directions: it also lets the SPP leak out as light. R. W. Wood saw unexplained dark bands in grating spectra in 1902 — these "Wood's anomalies" are partly SPP excitation.

Overview · more ways to supply momentum

Other excitation methods: anything small or fast works

Near-field tip (SNOM)

Light squeezed through a tip or aperture of size a contains in-plane wave vectors up to ~2π/a ≫ k0. A local, point-like SPP source — also used to image SPPs.

Scatterers and defects

A ridge, slit, hole or nanoparticle is a sharp feature. Its Fourier spectrum contains all kx, including β. Simple, but only a small fraction of light is coupled.

Fast electrons (EELS, cathodoluminescence)

An electron with speed v makes a field with kx = ω/v. Since v < c, kx > ω/c: phase matching comes for free. Basis of nanometre plasmon maps (lecture 4).

End-fire coupling

Focus a beam onto the cleaved end of a metal film or waveguide, so that the beam profile overlaps the SPP field profile. Used for long-range SPP waveguides (lecture 7).

A source that is localized in space is broad in k. Small (tip, defect) or slow-moving (electron) sources contain the large kx that free light lacks.
Derivation · SPR sensitivity

SPR sensing: a change of index shifts the resonance angle

1
Resonance condition with sample index n (take εm real for the derivative):\[ n_p\sin\theta = n_{\text{eff}}(n), \qquad n_{\text{eff}}^2 = \frac{\varepsilon_m n^2}{\varepsilon_m + n^2} \]
2
Differentiate both sides (prism fixed):\[ n_p\cos\theta\;d\theta = \frac{dn_{\text{eff}}}{dn}\,dn \]
3
Log-derivative: \(2\ln n_{\text{eff}} = \ln\varepsilon_m + 2\ln n - \ln(\varepsilon_m+n^2)\), so\[ \frac{dn_{\text{eff}}}{dn} = \frac{n_{\text{eff}}}{n}\,\frac{\varepsilon_m}{\varepsilon_m+n^2} = \left(\frac{n_{\text{eff}}}{n}\right)^{3} \]
Used εm/(εm+n²) = neff²/n² from step 1.
4
Sensitivity (radians per refractive index unit, RIU):\[ S_\theta = \frac{d\theta}{dn} = \frac{(n_{\text{eff}}/n)^3}{n_p\cos\theta_{\text{SPR}}} \]

Numbers: Au / water, 633 nm

(1.445/1.333)³ = 1.084³ = 1.274
np cos θ = 1.515 × cos 72.5° = 0.456
Sθ = 2.79 rad/RIU = 160°/RIU
Full Fresnel dip (50 nm film): 148°/RIU

Sanity check ✓

Bare critical-angle refractometry (no metal): S = 1/(np cos θc) ≈ 80°/RIU. The gold film roughly doubles it (≈ 160°/RIU) and adds a sharp minimum that is easy to locate.

Physical meaning

Binding molecules raise n in the SPP field → neff rises → the dip moves to a larger angle (small cos θ makes Δθ large).

Sθ is the bulk sensitivity (the whole field region changes index); a thin molecular layer counts only through its overlap with the field, ∝ 1 − e−2t/δ.

Worked example

Find θSPR and its shift for Δn = 10⁻³

50 nm gold (ε = −11.8 + 1.2i) on BK7 (np = 1.515), water (n = 1.333), λ0 = 633 nm

1
Critical angle: θc = arcsin(1.333/1.515) = 61.6°
The dip must lie above it.
2
Estimate (bare interface, slide 7): neff = 1.445 → θSPR ≈ 72.5°
3
Exact (Fresnel, d = 50 nm; minimize R(θ) numerically): θSPR = 72.21°, Rmin = 0.006
4
Linear estimate of the shift:\[ \Delta\theta \approx S_\theta\,\Delta n = 160^\circ/\text{RIU}\times10^{-3} = 0.16^\circ \]
5
Exact (Fresnel with n = 1.334): dip at 72.35° → Δθ = 0.148° = 2.6 mrad
n = 1.333n = 1.334 θ (degrees) — zoom near the dip R

Physical meaning

Δn = 10⁻³ moves the dip by only 0.15°, while the dip is ≈ 5.6° wide. Instruments locate the minimum by fitting, to ~10⁻⁴ degree.

Measurement · how to read the shift

Three ways to interrogate an SPR sensor

Angle interrogation

Fixed λ, scan θ (or use a fan of angles and a camera). Track the dip angle: S ≈ 150°/RIU for Au in water at 633 nm. Most common.

Wavelength interrogation

Fixed θ, white light and a spectrometer. Track the dip wavelength (nm per RIU). No moving parts; works well with optical fibres.

Intensity interrogation

Fixed θ and λ on the steep side of the dip. Our curve: slope 0.32 per degree at 70.7° → Δn = 10⁻³ changes R by 0.044. Simple and fast; basis of SPR imaging.

Physical meaning

All three read the same thing: neff of the SPP. Good instruments resolve ~10⁻⁶ RIU — far below the 10⁻³ of our example.

Measured SPR reflectance curves for a gold film, after a polymer layer, and after a clay layer
Measured SPR curves: bare gold (~38 nm), + polymer film, + clay film (air side). Tomio- (data T. Haraszti) · CC BY-SA 3.0

Each adsorbed nanometre-thin layer shifts the dip to a larger angle — qualitatively as predicted (a thin layer counts only through its overlap with the field, ∝ 1 − e−2t/δ).

Design · figure of merit and penetration depth

Sharp dips, stable metals, and a surface-only field

\[ \text{FOM} = \frac{S_\theta}{\Delta\theta_{1/2}} \quad\left[\text{RIU}^{-1}\right] \]
sensitivity divided by the full width of the dip at half depth
50 nm film, water, 633 nmgoldsilver
εm−11.8 + 1.2i−18.3 + 0.48i
θSPR (BK7)72.2°67.8°
Sθ (Fresnel)148°/RIU116°/RIU
width Δθ1/25.6°1.05°
FOM≈ 26 RIU⁻¹≈ 110 RIU⁻¹

So why does everyone use gold?

Silver tarnishes (Ag₂S) and dissolves in buffers. Gold is inert, and thiol (–SH) chemistry builds clean receptor layers on it. Stability beats sharpness.

Au distance from gold z (nm) |E|²/|E(0)|², SPP intensity in water

Penetration depth into water (computed): field 1/e at 180 nm, intensity 1/e at 90 nm. A 5 nm protein layer sits in the strongest field; things beyond ~200–300 nm are nearly invisible.

Physical meaning

SPR is surface-specific: it weighs what binds to the gold. But bulk index changes (temperature, buffer) still shift the dip, so instruments use a reference channel.

Real instruments · binding curves

The sensorgram: watching molecules bind in real time

time (s) → response (RU)
1
Rate equation (receptor sites Rmax, analyte concentration C):\[ \frac{dR}{dt} = k_aC\,(R_{\max} - R) - k_dR \]
2
Solutions: association \(R = R_{eq}\big(1 - e^{-(k_aC + k_d)t}\big)\), dissociation \(R = R_0\,e^{-k_dt}\); affinity \(K_D = k_d/k_a\).
Plot: ka = 10⁵ M⁻¹s⁻¹, kd = 2 × 10⁻³ s⁻¹, C = 50 nM → KD = 20 nM.
Biacore 3000 SPR instrument
Biacore 3000 SPR instrument · PlaxcoLab · CC BY 2.0
Biacore sensorgram, four concentrations of one protein
Real sensorgrams, one protein at 4 concentrations · Narayanese · CC BY-SA 3.0

1 RU ≈ 10⁻⁴ degree ≈ 1 pg of protein per mm².

Applications

Where SPR coupling is used beyond the biology lab

SPR imaging and arrays

Image the whole chip at fixed angle (intensity mode): hundreds of spots, each with a different receptor, read in parallel. Label-free screening of drugs and antibodies.

Gas and chemical sensing

Coat the gold with a layer that swells or changes index when it takes up a gas or solvent vapour. The dip follows the uptake.

Fibre and chip sensors

Strip the cladding of an optical fibre and coat it with gold: the guided light is in TIR, and wavelength interrogation reads the dip. Small, cheap, remote.

Plasmonic couplers on chips

Gratings and tapers convert light in silicon waveguides into SPPs and back: compact modulators, detectors and heat-assisted magnetic recording heads.

A laboratory surface plasmon resonance device
A laboratory SPR device · Laundry · public domain

Common thread

Every application uses the same two facts from today: a phase-matching element (prism, fibre, grating) and a resonance that moves with neff.

Check your understanding · click a card to reveal

Concept check

Q1. You shine p-polarized light from air onto a smooth gold film at 80°. Why is no SPP excited, however carefully you tune the angle?
kx = k0 sin θ ≤ k0, but β = 1.045 k0. The in-plane momentum never matches.
Q2. In a Kretschmann sensor with water, you swap the BK7 prism (1.515) for a cheap one with np = 1.40. Does it still work?
No. You need np sin θ = neff = 1.445, but np sin θ ≤ 1.40. The prism index must exceed neff.
Q3. A gold grating with Λ = 606 nm couples 633 nm light at normal incidence in air. You cover it with water. What period do you now need?
Λ = λ0/neff = 633/1.445 ≈ 438 nm. The SPP wavelength gets shorter in water.
Q4. Why does an SPR sensor respond strongly to a 5 nm protein layer but hardly to bacteria 1 µm thick sitting on the chip?
The SPP field decays within ~180 nm in water. Only the part of the bacterium near the gold is "seen".
Wrap-up

Summary and homework

1
On a flat surface, k0 sin θ ≤ k0 < β: free light cannot launch an SPP. Frequency and in-plane wave vector must match.
2
Prism (TIR evanescent wave): k0np sin θSPR = Re β. Kretschmann (film on prism) or Otto (gap). Au/water/BK7, 633 nm: θSPR = 72.2°, d ≈ 50 nm.
3
Grating: k0 sin θ + m 2π/Λ = ±Re β; normal incidence Λ = λSPP (606 nm, Au/air).
4
Sensing: Sθ = (neff/n)³/(np cos θ) ≈ 150°/RIU; FOM = S/width; field depth ≈ 180 nm → surface-specific.

Homework 6 (due Week 7)

  • Kretschmann (BK7, water): repeat the worked example for 50 nm Ag at 633 nm and for Au at 785 nm (ε ≈ −22 + 1.4i). Find θSPR (estimate and Fresnel) and the shift for Δn = 10⁻³.
  • Grating: find Λ for normal-incidence coupling on Au in air and in water; then for θ = 20° in air (both orders).
  • Film thickness: plot R(θ) for d = 20…70 nm. Find the d with the deepest dip and explain with critical coupling.

Project proposal due this week

One page: topic, key question, planned calculation or simulation, and three references.

Next lecture

Multilayers: thin films, gap plasmons, and plasmonic waveguides.

References and image credits

Further reading

Reading for this week

  • S. A. Maier, Plasmonics: Fundamentals and Applications, Springer (2007), Ch. 3 (excitation of SPPs).
  • E. Kretschmann & H. Raether, Z. Naturforsch. A 23, 2135 (1968) — radiative decay of non-radiative surface plasmons excited by light.
  • A. Otto, Z. Physik 216, 398 (1968) — excitation of non-radiative surface plasma waves by frustrated total reflection.
  • H. Raether, Surface Plasmons on Smooth and Rough Surfaces and on Gratings, Springer Tracts in Modern Physics 111 (1988).
  • J. Homola, Chem. Rev. 108, 462 (2008) — surface plasmon resonance sensors for detection of chemical and biological species.
  • B. Liedberg, C. Nylander & I. Lundström, Sensors and Actuators 4, 299 (1983) — first SPR biosensing.
  • R. W. Wood, Phil. Mag. 4, 396 (1902) — anomalous diffraction gratings.
  • Optical constants: P. B. Johnson & R. W. Christy, Phys. Rev. B 6, 4370 (1972) (values rounded).

All schematics and plots were drawn for this course; reflectance curves, dispersion, field decay and sensorgram are computed from the formulas shown.

Image credits (Wikimedia Commons)

  • Double prism tunneling: Jochen Magnus (original), derivative by Gregor Shapiro, public domain — File page
  • SPR adsorption data: Tomio- at English Wikipedia (data T. Haraszti), CC BY-SA 3.0 — File page
  • Biacore 3000 SPR instrument: PlaxcoLab, CC BY 2.0 — File page
  • Biacore sensorgram: Narayanese at English Wikipedia, CC BY-SA 3.0 — File page
  • Surface plasmon resonance device: Laundry, public domain — File page