Gold sphere in water (εd = 1.77): resonance ≈ 520 nm, independent of size as long as a ≪ λ.

Li measures how strongly the particle's own surface charges push back. Along a long axis the charges are far apart → small Li; across a thin axis they are close → large Li.
| shape | Li | resonance |
|---|---|---|
| sphere, a = b = c | 1/3 | ε′ = −2εd (Fröhlich) ✓ |
| needle, long axis | → 0 | ε′ → −∞ (far red) |
| flat disk, normal axis | → 1 | ε′ → 0 (blue) |
Sphere in step 2: 4πa³(ε−εd)/(3εd + ε − εd) = lecture 9 ✓
Small Li → weak restoring force → the electrons need a more negative ε′, which a Drude metal gives at longer wavelengths.
| R | L∥ | ε′ needed in water |
|---|---|---|
| 1 (sphere) | 0.333 | −3.6 |
| 2 | 0.174 | −8.5 |
| 3 | 0.109 | −14.6 |
| 4 | 0.075 | −21.8 |
| 5 | 0.056 | −30.1 |
On a long rod the opposite charges pile up at the two ends, far apart. Their restoring force is weak, so the electrons oscillate more slowly → a redder resonance.
Quasi-static spheroid in water, εAu(λ) from a 6-parameter Drude–Lorentz fit to Johnson–Christy values at 450–700 nm (approximate; extrapolated beyond 700 nm).
Model: R = 2 → 590 nm, R = 3 → 671 nm, R = 4 → 758 nm, R = 5 → 848 nm. Real rods (rounded ends, surfactant coating) sit somewhat redder, same trend.
Longitudinal (E along the rod, small L∥): strong, tunable, red/NIR. Transverse (E across, L⊥ ≈ 0.41–0.47): weak, stays near the sphere value.
Tissue absorbs least at 700–1100 nm. Rods with R ≈ 4 absorb there → light-driven heating of tumors (photothermal therapy, lecture 13).
Charge crowds into the corners. Sharper corners → resonance shifts red and the field at the corners is stronger than on a sphere.
Thin and wide like a flattened ellipsoid: in-plane L is small → red to NIR resonance; the sharp tips give the strongest local fields.
Dielectric core + thin metal shell. A thinner shell (relative to the core) → redder resonance: tunable from the visible into the NIR. Why: hybridization of inner and outer surface plasmons (lecture 11).
ka → 0: both terms vanish → quasi-static α.
The radiation term is the one that gives σsca = k⁴|α|²/6π via energy conservation (optical theorem): the energy scattered must be taken from the oscillator.
A big particle is both a better antenna (it loses energy by radiating) and "too big to oscillate in step" (it resonates redder).
| radius a | ħAvF/a | ħγ(a) total |
|---|---|---|
| 20 nm | 0.046 eV | 0.066 eV |
| 10 nm | 0.092 eV | 0.11 eV |
| 5 nm | 0.18 eV | 0.20 eV |
| 2.5 nm | 0.37 eV | 0.39 eV — ≈ 20× bulk |
Total = 0.02 eV + ħAvF/a (same base as the plot); vF(Au) = 1.4 × 10⁶ m/s, ħvF = 0.921 eV·nm, A = 1.
Peak height in this model: 1, 0.83, 0.71, 0.55 for bulk, 10, 5, 2.5 nm. Very small gold clusters lose their plasmon color; below ~2 nm they become molecule-like clusters (beyond this course).
Line width ↔ energy lifetime: τ = ħ/ħΓ, e.g. ħΓ ≈ 0.12 eV → τ ≈ 5.5 fs. The energy leaves by radiation (scattering) or non-radiatively into electron–hole pairs (heat, hot electrons — lecture 13).
Expand all fields in spherical multipoles, match at r = a → coefficients an, bn:\[ \sigma_{\text{ext}} = \frac{2\pi}{k^2}\sum_{n}(2n+1)\,\mathrm{Re}(a_n + b_n) \]n = 1 dipole, n = 2 quadrupole… Exact for any size.
Size parameter x = ka = 2πnda/λ₀. At 520 nm in water: x = 0.3 at a ≈ 19 nm, x = 0.5 at a ≈ 31 nm.
| radius a | D = 2a | x (520 nm) | QS | MLWA | Mie (exact) |
|---|---|---|---|---|---|
| 10 nm | 20 nm | 0.16 | 523 | 525 | 524 |
| 20 nm | 40 nm | 0.32 | 523 | 532 | 530 |
| 40 nm | 80 nm | 0.64 | 523 | 568 | 553 |
| 80 nm | 160 nm | 1.29 | 523 | 791 | 658 + quadrupole |
Extinction peaks (nm), gold in water, same ε(λ) fit. QS column: the Fröhlich absorption peak, 523 nm (lecture 9's table for D = 80 nm showed the QS extinction peak, 528 nm). MLWA: σext = k Im αMLWA (slide 9). Mie: our own Mie code (Bohren–Huffman algorithm).
Quasi-statics is good to a few nm up to a ≈ 20 nm (x ≈ 0.3); by a ≈ 30–40 nm it misses by 15–30 nm. MLWA helps up to x ≈ 0.5, then overshoots. Beyond that: Mie (or numerics for other shapes).
| particle (gold, water) | m (nm/RIU) |
|---|---|
| sphere, Drude estimate (step 4) | ≈ 100 |
| sphere, QS, fitted ε(λ) | ≈ 70–75 |
| sphere a = 30 nm, Mie | ≈ 110 |
| spheroid R = 2 / 3 / 4, QS | ≈ 170 / 280 / 370 |
Same steps with \(\varepsilon' = -(1/L - 1)n_d^2\):\[ m = \frac{(1/L-1)\,\lambda_p n_d}{\sqrt{\varepsilon_\infty + (1/L-1)n_d^2}} \]Small L multiplies the shift. Measured rods: ~200–400 nm/RIU.
A denser medium screens the surface charges, weakening the restoring force → red shift. The redder the resonance, the larger the shift per unit nd.
Example: rods, m = 200 nm/RIU, δd = 10 nm; a 5 nm protein layer (n ≈ 1.45, Δn = 0.117): Δλ = 200 × 0.117 × 0.63 ≈ 15 nm.
LSPR fields decay within δd ≈ 5–15 nm (vs ≈ 180 nm for a flat SPP, lecture 6). Only molecules bound right at the particle count; changes in the bulk solution matter much less → good for small molecules, insensitive to far-away noise.

Target molecules link particles together; neighbors couple and the resonance jumps red: the solution turns from red to purple-blue — visible by eye (coupling: lecture 11).

Gold-nanoparticle lines seen by eye (lecture 9).

Red in transmission, green in reflection (lecture 9).
Nanoparticle chips or single particles; track the peak shift (slide 13) as molecules bind. Label-free, simple optics, nanoscale sensing volume.
Rods (R ≈ 4) or nanoshells absorb in the NIR window; absorbed light → heat → local tumor killing (lecture 13).
Shape sets the color, size sets absorption vs scattering and width, environment sets the shift.
It is the benchmark for every numerical method you will use later (FDTD in Lab 4).
Two particles close together: coupled dipoles, plasmon hybridization, nanogaps and hot spots, the plasmon ruler, Fano resonances, and the quantum limit of tiny gaps.
Lab 3 this week · Homework 9 due Week 11 · project progress check in Week 11.
All schematics and plots were drawn for this course. Numbers come from the formulas shown, with a Drude–Lorentz fit to Johnson–Christy gold (approximate) and our own Mie code.